Refers to the total resistance of the contact resistance between the
contacts and the sum of the conductors connected to the contacts and
the conductors at the terminals. Generally expressed in mΩ.
Unless otherwise stated in the specification, a relay with a contact
load less than 1A generally uses 6Vd.c., 0.1A to measure contact
resistance, and a contact with a contact load greater than 1A uses
6Vd.c., 1A to measure contact resistance.
What Is Contact Resistance For Relays